CLT10 sc Sensore per il cloro totale con sensore differenziale pHD (su pannello)

CLT10 sc Sensore per il cloro totale con sensore differenziale pHD (su pannello)
Codice articolo: LXV45B.98.23022
Prezzo unitario Contatti
Spedizione entro 2 settimane

Disinfezione sotto controllo

The CLF10 sc and CLT10 sc Chlorine Analysers are designed to be used with all Hach digital SC controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors.

Costi di esercizio minimi

Chlorine measurement with the CLF10 sc and CLT10 sc amperometric technology eliminates the need for routine reagent replacement and waste stream management.

Plug & play

The CLF10 sc and CLT10 sc analysers can be used for reporting chlorine residual measurements in accordance with EPA Method 334.0. Additionally, Hach has created a suite of laboratory products and methods to help with startup and quality control procedures required for Method 334.0.

Controllo dei processi in tempo reale

CLF10 sc and CLT10 sc advanced diagnostics alert you when the process has changed or the instument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting sample flow sensor for notification of insufficient sample flow.

Conforme ai requisiti EPA secondo la metodica 334.0

The CLF10 sc and CLT10 sc Chlorine Analysers allow for real-time monitoring and control of disinfection processes.

Contenuto della confezione

CL10sc Panel, 1 m Digital Extension Cable, pHD Differential Sensor, Panel Manual, Chlorine Sensor Manual, pHD Sensor Manual

Specifiche tecniche

Accuratezza: Free Chlorine: ± 3 % of the reference test** (DPD) at constant pH less than 7.2 (±0.2 pH unit)
  Free Chlorine: ± of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
  Total Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
  Total Chlorine: ± 20 % of the reference test** (DPD) at stable pH greater than 8.5
Cavo di collegamento: 5 pin, M12 connector
Centralina: Panel only
Certificazioni: CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)
Additional certifications when connected to an sc controller
Collegamento: ¼" OD
  ½" ID
Compatibilità centralina: SC200, SC1000, SC4500. All controllers sold separately
Compensazione della temperatura: Compensazione della temperatura interna nel sensore
  Internal temperature compensation in the sensor
Condizioni di stoccaggio: -20 °C - 60 °C dry
Contenuto della confezione : CL10sc Panel, 1 m Digital Extension Cable, pHD Differential Sensor, Panel Manual, Chlorine Sensor Manual, pHD Sensor Manual
Descrizione: CLT10sc Total Chlorine Sensor pHD Differential Sensor (On Panel)
Dimensioni: Sensor Only: 195 mm x 25 mm (7.68 in x 0.98 in)
Garanzia: 24 mesi
Interferenze: Cloro libero: monocloroammine, biossido di cloro, ozono e carbonati. Cloro totale: biossido di cloro, ozono e carbonati.
Intervallo di misura: 0 - 20 ppm Cl₂
Intervallo di pressione: 0.5 bar, no pressure impulses and/or vibrations
Intervallo pH: 4 - 9 pH
Larghezza: 495.3 mm
Limite di rilevamento: 30 ppb (0.03 ppm)
lunghezza: Sensor: 195 mm
Lunghezza del cavo: 1 m (between gateway and SC controller)
Materiale: Panel: Corrosion-resistant, fully-submersible (stainless steel, PVC, silicon rubber and polycarbonate)
Metodo di misura: Reagentless, electrochemical, three-electrode amperometric system
Metodo di taratura: 1-point or 2-point (zero and slope) calibration
Montaggio: Panel or Wall Mounting
Opzioni: pHD Differential Sensor
Parametro: Total Chlorine
Peso: Approximately 5.5 kg
Panel and empty panel-mounted components only
pH Monitoring Required?: with pHD Differentinal (on panel)
Portata: Metric
Requisiti Alimentazione (Voltaggio): None
Ripetibilità: 30 ppb o il 3 %, qualunque sia il maggiore
Temperatura del campione: 5 - 45 °C
Temperatura di lavoro: 0 - 45 °C
Tempo di risposta: Free Chlorine: 140 s or less for 90% change (T90)
at a stable temperature and pH
  Total Chlorine: 100 s or less for 90% change (T90)
at a stable temperature and pH
Velocità di flusso del campione: 30 - 50 L/h (7.9 - 13.2 gal/ora), valore ottimale 40 L/ora (10.5 gal/ora)