5500sc Ammonia Monochloramine Analyser, 2 Channel

5500sc Ammonia Monochloramine Analyser, 2 Channel
Codice articolo: 5500.AMC.2.KTO
Prezzo unitario Contatti

Easy operation

The analyzer offers an easy-to-operate, low-maintenance solution to help you maintain the proper chlorine to ammonia ratio and assure there is no free ammonia in your system that could lead to nitrification. We removed the traditional pumps associated with reagent delivery and replaced them with a pressurized system to eliminate the hassles and maintenance that pumps can cause.

Reliability without all the work

With Prognosys, the analyzer’s onboard predictive diagnostic software, you will have early insight into the measurement reliability and service requirements of your instruments. A user-friendly interface, color coded reagent bottles and at-a-glance status lights will offer peace of mind the instrument is up and running.

Improved control of your chloramination process

The 5500sc Ammonia Monochloramine Analyzer provides continuous monitoring, so you can trust that your instrument is giving you the information you need to control your chloramination process.

Contenuto della confezione

Hach 5500sc Ammonia Monchloramine Analyser, 2 channels, with installation kit and user manuals, reagents and standards for one month use

Specifiche tecniche

Accuratezza: ± 5 % or 0.01 ppm (as N) for sample temperature 5 - 40 °C (41 - 104 °F); ±10% or 0.02 ppm for sample temperature 40 - 50 °C (104 - 122 °F), whichever is greater
Allarme: Four; not powered SPDT relays, each rated at 5A resistive, 240 VAC maximum
Campione: pressione: 2,5 - 87 psi (0,17 - 6,8 bar)
Certificazioni: CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000
cETLus (UL 61010-1:2012; NEMA 250:2003; CSA C22.2 No 61010-1:2012)
Australian RCM Marking
Comunicazione: Modbus RS485, Profibus DP (available with external controller), 4-20mA Output
Condizioni di stoccaggio: -20 - 60 °C (-4 to 140 °F)
Consumo reagente: 1L of reagents every month with 5 minute cycle time
Contenuto della confezione : Hach 5500sc Ammonia Monchloramine Analyser, 2 channels, with installation kit and user manuals, reagents and standards for one month use
External Filter: No
Garanzia: 24 mesi
Grado di protezione : IP56 / NEMA 4X
Ingresso: 6 mm OD push-to-connect fitting for plastic tubing
Intervallo di misura: 0,01 - 2 ppm (come N), 0,1 - 10,0 mg/L (come Cl₂)
  4.5 minutes
Limite di rilevamento: 0.01 ppm (as N)
Livello di inquinamento: 2/II
Materiale: Polycarbonate (PC)/ABS case, PC Door, PC hinges and latches, 316 Stainless Steel hardware
Montaggio: Wall, panel, or table
No. di canali: 2
No. Di flussi campione: 1 or 2 in programmable sequence
Opzioni: Standard
Parametro: Total Ammonia, Monochloramine, and Free Ammonia
Peso: 20.5 kg (45.19 lb) without reagents and standards, 30 kg (66.14 lb) with reagents, standards and cleaning solution
Presa campione manuale: Grab Sample In and Grab Sample Out capability
Requisiti Alimentazione (Hz): 50 - 60 Hz
Requisiti Alimentazione (Voltaggio): 100 - 240 VCA
Ripetibilità: 3 % or 0.01 ppm (as N), whichever is greater
Scarico: 11 mm (7/16 in.) ID slip-on fitting
Sorgente luminosa: Class 1M LED (light emitting diode) with a peak wavelength of 650 nm
Temperatura del campione: 5 - 50 °C (41 - 122 °F)
Temperatura di lavoro: 5 - 45 °C (41 - 113 °F)
Tempo di analisi: 4.5 min
Tempo di risposta: Within 5 minutes
Umidità operativa: 5 - 95 % in assenza di condensa
Uscita: Four 0/4-20 mA Outputs, load impedance 600 ohm maximum
Velocità di flusso del campione: 100 - 1000 mL/min